MSJOBCMD
MiddleMan • ODBC/32 • JDBC • NFT
You can control the MSJOB processes through either of these two utilities:
-
Windows based Server Console
- HP e3000 based MSJOBCMD
MSJOBCMD
You must have SM or OP capability to use this utility.
The ‘loopback’ feature of you network interface must be started. Use “NETCONTROL START;NET=LOOP”
This application is designed to run from a JOB or SESSION on the HP e3000 that is running the Minisoft Client Server listener (MSJOB). The purpose of this utility is to display the current users of MSJOB and to optionally stop the MSJOB.
Options
- PARM=0
- Display current listeners and connections.
- PARM=1
- Display current listeners and connections. If no current connections, then stop the job or listener.
- PARM=2
- Display current listeners and connections. Stop the job or listener regardless of the users.
- PARM=3
- Display current listeners and connections.
- PARM=4
- Start a listener using the INFO parameter. Use a format similar to the MSJOB indirect file.
INFO="5|30007|0|JDBCSRVR.MM.MINISOFT;PRI=DS S"
- PARM=5
- Kill all processes of a listener, leave the listener active.
- INFO=(port number)
- Port number to use for above commands. If not given, then PARM values apply to job.
Details
RUN MSJOBCMD;PARM=0 Will display the current users.
RUN MSJOBCMD;PARM=1 Will display the current users and optionally stop the job if the number of users is zero.
RUN MSJOBCMD;PARM=2 Will display the current users and stop the job regardless of the number of users.
RUN MSJOBCMD;PARM=2;INFO=”30006″ Will display the current users for the listener on port 30006 and stop the it regardless of the number of users.
Output JCWs
-
MSJOBUSERCOUNT
MSJOBSHUTDOWN
MSJOBUSERCOUNT is used to display the total number of active server connections on this server. The value will be -1 if there is an error.
MSJOBSHUTDOWN will be set to TRUE if a shutdown command is sent to the JOB. Otherwise it will be set to FALSE.
Input JCWs
-
MSJOBPORT
MSTIMEOUT
MSTRACE
Set MSJOBPORT to the value of your MSSERVER port. The default value is 30000.
Set MSTIMEOUT to the number of seconds to wait for a connection. The default is 60.
Set MSTRACE to 7 to display the version number. The default is zero.
(Version 1.1.0.2)
Added support to isolate an individual listener based upon port number given in the INFO parameter.
(Version 1.2.1.0)
-
Added PARM=4 and 5
Update
-
Updates are available to support this feature. Please contact your Minisoft Sales or Support office about receiving this update.
-
* This will replace ALL MiddleMan files on your system. Be sure to have a current backup before proceeding.
Example:
-
!JOB STOPRUN,MANAGER.SYS
!SETVAR MSJOBPORT 31000
!SETVAR MSTIMEOUT 20
!RUN MSJOBCMD.MM.MINISOFT;PARM=1
!if msjobshutdown
!echo job down
!else
!echo Users on MSJOB: !msjobusercount
!endif